HXGN-12 Ring Main Unit

A 12 kV box-type fixed ring main unit for compact ring-network distribution — the economical alternative to a full metal-clad switchgear lineup.

What Is HXGN-12 Ring Main Unit?

Where a substation needs to distribute power around a ring rather than feed a single transformer through a dedicated breaker bay, a ring main unit is the standard economic answer. The HXGN-12 covers the terminal and branch positions that make up most distribution ring line-ups.

The HXGN-12 is a box-type fixed AC metal-enclosed switchgear built as a ring main unit. The primary switching element is an SF6 load-break switch (FLN36-12 / FLN48-12 type, or ABB SFG) and transformer circuits use a load-break switch and fuse combination. Units are supplied in standard widths that combine into multi-circuit ring line-ups and branch feeders.

HXGN-12 box-type ring main unit for 12kV ring network distribution

How It Works

Three-position switching — closed, open and earthed — makes the earthing position visually obvious and gives operators a defined isolation point before work starts. In a ring network the same busbar section appears in several cabinets, so a fault or a planned outage on one section is fed from the other direction. Transformer protection is provided by the fuse inside the combined unit, which removes the need for a separate breaker bay in the common terminal-type installation.

  • Three-position load-break switch: closed, open and earthed, with visible earthing position.
  • Load-break switch and fuse combination units for transformer protection.
  • Standard unit widths that combine into multi-circuit ring line-ups and branch feeders.
  • Manual or electric operating mechanism; FTU / RTU integration available for distribution automation.
  • Optional VS1, VD4/S or ISM vacuum breaker versions where breaking of full short-circuit current is required.

HXGN-12 Technical Specifications

ParameterTypical value
Rated voltage12 kV
Rated frequency50 Hz
Main busbar rated current630 A (up to 1250 A on request)
Branch busbar rated current400 / 630 A
Load-break switch typeFLN36-12 / FLN48-12 SF6 load-break switch, or ABB SFG
Rated short-circuit making current (peak)50 kA
Rated short-time withstand current20 kA, 2 s
Rated peak withstand current50 kA
Power frequency withstand voltage (1 min)42 kV phase-to-phase and to earth, 48 kV across the isolating gap
Lightning impulse withstand voltage (peak)75 kV phase-to-phase and to earth, 85 kV across the isolating gap
Protection classIP2X to IP3X
Operating mechanismManual or electric, with optional FTU/RTU automation
Ambient temperature-35 °C to +40 °C
AltitudeUp to 1000 m without derating
ComplianceGB/T 3906-2020, GB/T 11022-2020, IEC 62271-200

Industry reference values for this equipment type. They describe the common rating range of the category and are not XINSHENG ELECTRIC-specific factory figures. Final values are confirmed in the technical agreement and order drawing.

How lead time is counted10 days for standard models and 15 days for customized configurations. The clock starts on the day we receive your deposit, the confirmed technical agreement and the approved general arrangement drawing — not on the order date. MOQ is 1 unit.

Typical Applications

  • Urban and rural 10 kV ring-network distribution
  • Box-type package substation high-voltage unit
  • Branch feeders and small open substations
  • Residential compound ring supply
  • Street lighting and public lighting MV feeders

Customization Options

  • Unit configuration: incoming, outgoing, transformer, PT and metering sections
  • Electric operating mechanism with remote indication for distribution automation
  • FTU / RTU integration for fault indication and remote control
  • Alternative breaker types: VS1, VD4/S, ISM vacuum or HD4/SS SF6
  • Enclosure colour and cabinet dimensions matched to the site layout

How to Select

Decide first whether the ring needs a fault-break capability or a fuse-protected transformer branch — that choice determines the unit type. Then count the ring sections: each additional circuit means another cabinet width, and the layout has to allow cable entry from the correct side. Check the site altitude and ambient temperature against the standard condition, and confirm whether distribution automation (FTU/RTU) is required by the utility, because that adds both cabinet space and a communications scope.

Frequently Asked Questions

What is HXGN-12 and how does it differ from KYN28A-12?

HXGN-12 is a fixed, box-type ring main unit built around an SF6 load-break switch, sometimes combined with a fuse for transformer protection. KYN28A-12 is a withdrawable metal-clad cabinet built around a vacuum circuit breaker. The RMU is more compact and cheaper and suits ring distribution; the KYN28A-12 is required where full short-circuit current must be interrupted.

Can an HXGN-12 interrupt a full short-circuit current?

The load-break switch alone cannot. In transformer circuits the fuse inside the combined unit clears the fault. If the incoming position of the ring must interrupt the full short-circuit current, specify the breaker version instead.

What is the rated current of a standard HXGN-12?

The main busbar is rated 630 A as standard, with 1250 A available on request. Branch busbar ratings are typically 400 A or 630 A, and fuse maximum rated current is 125 A for the standard ring main unit configuration.

Can HXGN-12 be used inside a package substation?

Yes. The high-voltage unit of a YB12 package substation is normally built from HXGN / XGN15 ring main units, so the same equipment type appears in both outdoor kiosks and indoor ring line-ups.

Is distribution automation available?

Yes. Electric operating mechanisms with remote indication and FTU / RTU integration can be specified for feeder automation, fault passage indication and remote control.

What standards does the HXGN-12 comply with?

GB/T 3906-2020 and GB/T 11022-2020, with IEC 62271-200 as the international reference. Routine factory test reports are supplied with each unit.

What is the lead time and MOQ?

10 days for standard configurations and 15 days for customized arrangements, counted from deposit plus confirmed technical agreement plus approved drawing. MOQ is 1 unit.