YB12 Package Substation

A prefabricated outdoor substation combining the HV ring main unit, the distribution transformer and the LV switchgear in one factory-assembled enclosure.

What Is YB12 Package Substation?

The package substation is the single most cost-effective way to deliver a complete distribution point to a site with limited civil works. Because the assembly and the wiring are done in the workshop, the site scope reduces to foundation, cable termination and commissioning.

The YB12 is a three-in-one outdoor package substation: the high-voltage ring main unit, the distribution transformer and the low-voltage switchgear are installed inside a single prefabricated enclosure and connected in the factory. The customer receives a complete, tested distribution point that only needs cable connection on site, which removes most of the civil work and shortens the project critical path.

YB12 outdoor prefabricated package substation with corrugated steel enclosure

How It Works

High-voltage energy enters through the ring main unit section, where a load-break switch and fuse combination protects the transformer. The transformer steps the voltage down to 400 V and feeds the LV switchgear section, which carries the incoming breaker, the outgoing feeders and, where required, an automatic capacitor bank for reactive compensation. The enclosure uses a double-layer composite panel construction for thermal insulation and ventilation, and can be finished in stainless steel, aluminium, cold-rolled steel or colour-coated sheet.

  • High voltage, transformer and low voltage integrated in one prefabricated enclosure.
  • Double-layer composite panel enclosure with thermal insulation and natural ventilation.
  • Transformer options: low-loss sealed oil-immersed or resin-cast / NOMEX paper insulated dry type.
  • High-voltage section can be fitted with FTU for the four-remote functions (telecontrol, telesignal, telemetering and teleadjustment).
  • Enclosure material and RAL colour to the site or utility requirement.

YB12 Technical Specifications

ParameterTypical value
High voltage side12 kV, HXGN-12 or XGN15-12 ring main unit with load-break switch and fuse
TransformerSCB dry type or S13 / S20 / S22 sealed oil-immersed
Transformer rating100 / 125 / 160 / 200 / 250 / 315 / 400 / 500 / 630 / 800 / 1000 / 1250 / 1600 kVA
Low voltage side0.4 kV, incoming breaker, 4 to 12 outgoing feeders, metering
LV reactive compensationAutomatic capacitor bank up to 200 kvar
EnclosureDouble-layer composite panel; stainless steel, aluminium, cold-rolled or colour-coated steel sheet
Protection classIP33 standard, IP44 on request
Ambient temperature-25 °C to +40 °C
AltitudeUp to 2000 m
Relative humidityDaily average up to 95%, monthly average up to 90%
Installation siteFree of fire or explosion hazard, conductive dust, corrosive gas and severe vibration
ComplianceGB/T 17467-2020, DL/T 537-2018, GB/T 3906-2020, GB/T 7251.1-2023

Values shown are typical ratings for this product family. Final ratings, dimensions and component selection are confirmed in the technical agreement and the order drawing; routine factory test reports are supplied with each unit.

How lead time is counted10 days for standard models and 15 days for customized configurations. The clock starts on the day we receive your deposit, the confirmed technical agreement and the approved general arrangement drawing — not on the order date. MOQ is 1 unit.

Typical Applications

  • Industrial plants and construction site temporary supply
  • PV power plants — step-up from inverter 0.4 kV to 10 kV
  • Residential compounds, street lighting and municipal distribution
  • Military facilities, mining camps and remote sites
  • Commercial complexes, schools and hospitals without a dedicated substation room

Customization Options

  • Transformer rating, type (dry or oil-immersed) and vector group
  • Number of outgoing feeders and the outgoing breaker arrangement
  • Automatic capacitor bank size and switching scheme
  • FTU installation for four-remote distribution automation
  • Enclosure material, RAL colour and layout (P-type or M-type arrangement)
  • Additional sections for metering, PT or an SVG instead of a capacitor bank

How to Select

The transformer rating normally governs the whole package, because it fixes the enclosure dimensions and the outgoing feeder count that physically fits. Next, confirm the high-voltage arrangement: if the site is fed by a ring, the HV section needs an incoming and an outgoing ring unit; if it is a single feed, a transformer unit alone will do. Then fix the outgoing feeder schedule against the actual load list, and add the compensation only after the transformer rating is settled, since the compensation size is normally expressed as a proportion of the transformer capacity.

Frequently Asked Questions

What does a YB12 package substation include?

A high-voltage ring main unit with load-break switch and fuse, a distribution transformer, a low-voltage section with incoming breaker and outgoing feeders, metering and optional reactive compensation — all factory-assembled into one enclosure, pre-wired and factory-tested.

Which transformer ratings are available?

Standard from 100 kVA to 1600 kVA, with SCB dry type or S13 / S20 / S22 sealed oil-immersed transformers according to the project specification.

Can the enclosure colour be changed?

Yes. The enclosure is painted in any RAL colour to match site or utility requirements, and the material can be specified as stainless steel, aluminium, cold-rolled steel or colour-coated sheet.

What is the on-site scope?

The unit is delivered pre-wired and factory-tested. On site only cable connection is required — there is no assembly work, only the foundation and the terminations.

Can the package substation be fitted with distribution automation?

Yes. The high-voltage ring main unit can be equipped with an FTU to provide the four-remote functions of telecontrol, telesignal, telemetering and teleadjustment.

What is the protection class and the altitude rating?

IP33 as standard, IP44 on request. The factory altitude rating is up to 2000 m, which is higher than the common 1000 m industry figure.

What is the lead time?

10 days for a standard configuration and 15 days for a customized arrangement, counted from deposit plus confirmed technical agreement plus approved drawing.